RADIOGRAPHY (X-RAY) | Industrial X-ray Tubes, Generators & Controls
Portable X-ray Unit 300 kV Directional Radiating Tube Head, water-cooled

The X-ray tube head consists of a sturdy metal-ceramic X-ray tube and high voltage generator integrated into a rugged compact housing. The water-cooled 300 KV/ 900 W end-grounded X-ray tube is thermally protected for extended life.
The high voltage generator generates high-stability constant potential voltage at higher efficiency than conventional line frequency equipment.
The performance of the X-ray tube and the high voltage generator is continuously monitored for protection and operational safety. An on-board real time clock facilitates fully automatic warm-up routines for optimized and time-saving tube conditioning. The flexible connecting cable is heavy-duty and light weight.
Additional Features
• Rugged construction with proven reliability
• Gas insulated high voltage section reduces size & weight
• End-grounded, Be-window, metal-ceramic X-ray tube
• DC voltage operation
• Modern power electronics provides high stability
• On-board real time clock supports fully automatic warm-up
• Extended operating range from 5 kV to 300 kV enables flexible use
• Large 40° x 60° emergent beam
• Additional water-cooling for environments with limited heat-dissipation capabilities
• 100% duty cycle at 30° Celsius (86° F)
• Built-in fail-safe warning lamp
• CE certification according to EMC and Low Voltage Directives
• French Standard NFC 74 100 compliant
• Water / dust resistant in accordance with protection class IP65
• Produced under ISO 9001 certified quality management system
Technical data
|
X-ray tube type |
300 kV metal-ceramic with Tungsten (W) anode |
|
kV range |
5 - 300 kV (acc. to rating chart) |
|
Target angle |
20° |
|
Inherent filtration |
0.8 mm ± 0.1 mm, Be |
|
Emergent beam |
40° x 60°, elliptical |
|
Focal spot size (EN 12 543) |
3.0 mm (~1.5 IEC 336) |
|
Tube current |
0.5 - 6 mA (3.0 mA /300 kV) |
|
Anode temperature, max. |
100 °C |
|
Current and voltage stability |
± 1% |
|
Continuous rating |
900 W |
|
Duty cycle (δamb = 30° C) |
100 % (up to 60 min continuous operation) |
|
Power input, max. |
2.0 kVA |
|
Weight |
40 kg (88.2 lbs) |
|
37.5 kg (82.7 lbs) (without rings) |
|
|
Tube head diameter |
290 mm (11.42”) |
|
225 mm (7.87”) (without rings) |
|
|
Protection class |
IP65 |
|
Min. cooling water flow rate |
2.5 l/min |
|
Max. cooling water pressure |
10 bar |
|
Cooling water specification |
Drinking water |
|
Connector for water hoses |
diameter 11 mm (7/16”) |
|
Water filter necessary |
No |
|
Operating Temperature |
-20°C to +50°C |
|
Storage Temperature |
-30°C to +80°C |